News Center
dilo filter unit high-voltage separating unit

dilo filter unit high-voltage separating unit

PRE-FILTER AND SEPARATING UNITS Adsorption of humidity and decomposition products On the assumption that contaminated or humid gas is in the circuit breaker we recommend the use of pre-filters between switchgear and service cart. Moisture, gaseous and dusty decomposition products as well as oil ...

[email protected]

News Detail

  • ALTERNATIVE GASES - us.dilo.com

    Pre-filter unit (pe 10 bar) Technical data: Dimensions: Length 180 mm, Width 105 mm, Height 360 mm Weight: 4 kg Standard equipment: Dry filter Particle filter DILO couplings DN8 Operating manual Optional accessories at an extra charge: 2 m long wire braided hose DN8 with DILO coupling tongue part DN8 on both ends (M28) - C4 C4-6-1130-R020

    Get Price
  • SF Gas Handling 6 - 50hz Solutions

    DILO SF 6 gas handling medium and high voltage switchgear as an arc quenching and insulating gas. As SF 6 is a major greenhouse gas with high global warming potential listed in the Kyoto protocol it is Pre-filter and separation filter unit For safe absorption of moisture, gaseous and solid

    Get Price
  • High Voltage Service High Voltage Equipment Standard

    Pre-filter unit B077R01 dry filter particle filter DILO couplings DN8 Gas leak detector 3-033-R002 Microprocessor control, with advanced digital signal processing. Tricolor visual LED display and audible signal for progressive leak-size indication. Power supply 3 V = two 1.5 V “C” - cell alkaline batteries

    Get Price
  • DILO: Production Machines - DirectIndustry

    All DILO products . SF6 Gas refilling and evacuating devices. SF6 gas refilling device 3-001-R001. cylinder cart mobile for distribution switchgear. Filter units. gas pre-filter B007R11. PE. gas pre-filter B071R11. oil activated carbon separation. gas pre-filter B148R03. cartridge PE. MANIFOLDS. multi-channel manifold 3-718-R006.

    Get Price
  • AIR SEPARATION UNIT – Deha Tech

    Deha Tech Service AIR SEPARATION UNIT Producing industrial gases requires a great deal of energy, making the need for an efficient compressed air system critical to plant success. To produce industrial gases such as purified nitrogen or oxygen, atmospheric air is compressed, cooled, and separated in a distillation column or cold box.

    Get Price
  • Memory HiCorder | HIGH VOLTAGE UNIT 8961 - Hioki

    Key Features • Isorated input, up to 600 V AC, DC CAT III, 1000 V AC/DC CAT II (maximum rated voltage to earth) • 16-bit A/D high resolution measurement • DC, 40 Hz to

    Get Price
  • Hioki U8974 High Voltage Unit | TEquipment

    The Hioki U8974 input module features direct high –voltage input of up to 1000 V DC and 700 V AC without using a differential probe. This is ideal for primary and secondary measurements of UPS power supplies and commercial power supply transformers, for recording the primary and secondary waveforms of inverters, and for measuring high-voltage power supply lines, such as 380 V and 480 V

    Get Price
  • CN203688633U - Four-quadrant unit three-phase input

    The utility model discloses a four-quadrant unit three-phase input voltage sampling circuit of a high-voltage frequency converter. The circuit comprises an isolation step-down sampling circuit, a comparator circuit and a phase-locked loop circuit, wherein the isolation step-down sampling circuit is used for performing real-time isolation step-down processing on AC voltage signals; the

    Get Price
  • SF6 gas 160 plant recovery machines dilo

    SF6-GAS | DILO GmbH. DILO SF 6 gas handling Zero emissions and maximum gas re-use SF 6 is a non-toxic, inert insulating and quenching gas of high dielectric strength and thermal stability. Due to its first-class properties it is used in enclosed medium and high voltage switchgear as an arc quenching and insulating gas. Get Price

    Get Price
  • Proving Units and Proving Devices for Voltage testers and

    Proving units are essential within the safe isolation process as they provide a known voltage source to verify that a voltage tester is operating correctly, both before, and after checking for voltage.

    Get Price
  • Gas pre-filter - B007R11 - DILO - PE

    PRE-FILTER AND SEPARATING UNITS Adsorption of humidity and decomposition products On the assumption that contaminated or humid gas is in the circuit breaker we recommend the use of pre-filters between switchgear and service cart. Moisture, gaseous and dusty decomposition products as well as oil

    Get Price
  • SF6 decomposition filter unit prices

    SF6 decomposition filter unit prices. Convenient and portable handcart mounted SF6 Gas Recovery Unit. Extremely easy to operate. Ideally suited for consolidating partially-used SF6 bottles. Purifies, dries and filters SF6 to 0.1 micron during recovery and re-filling. [email protected]

    Get Price
  • Gas pre-filter - All industrial manufacturers - Videos

    DILO. gas pre-filter B071R11. oil activated carbon separation. gas pre-filter. B071R11. Operating pressure: 25 bar... separating filter unit (pe 25 bar) B071R11 For adsorption of oil-aerosols, moisture and gaseous or dusty decomposition products.

    Get Price
  • High Voltage Service High Voltage Equipment Standard

    High Voltage Equipment Standard service offering This is a collection of tools for every installation, every need, and for minor emergencies. Portable vacuum pump unit B078R06 – 10 m3/h vacuum pump with exhaust filter – final vacuum < 1 mbar – vacuum gauge (-1 to 0 bar) – ball valve DN8 – 3 m long rubber hose DN8 with DILO

edge-iconRelated News
toTop
Click avatar to contact us
Chat Online