News Center
dilo HV switchgear Insulating gas equipments

dilo HV switchgear Insulating gas equipments

Dilo was the first company ever to deal with the problem of handling sulfur hexafluoride (SF6) back in the 1960s. Sulfur hexafluoride is used as an insulating gas in electrical switchgear. Dilo has developed technical solutions that prevent this climate-damaging gas from entering the Earth's atmosphere.

[email protected]

News Detail

  • High-quality gas handling – DILO is updating its SF gas

    for example in gas-insulated switchgear or pipe systems. Thanks to its excellent arc quenching properties (100 times faster than air), it is the medium of choice for encapsulated medium and high-voltage switchgear. In addition, SF 6 is also used in medical devices, semiconductors, displays and microtechnology applications. DILO’s

    Get Price
  • DILO | CEPCO Sales

    Dilo 3-027-R002 SF6 Gas Volume Percentage Measuring Devices; Dilo 3-032-R Portable SO2 Gas Measuring Devices; Dilo 3-037-R001 SF6 Moisture Measurement Devices; Dilo Compact Series B057R03 SF6 Gas Service Carts for Liquid Storage; Dilo Compact Series B057R17 SF6 Gas Service Carts for High Voltage Switchgear; Dilo Compact Series B058R03 SF6 Gas

    Get Price
  • Dilo Compact Series B058R03 SF6 Gas Service Carts for High

    For easy maintenance on high voltage switchgear. B058R03 . This robust series comprises several versions allowing gaseous and liquid SF 6 storage. SF 6 gas can be recovered to a final vacuum of < 5 mbar or 1 mbar and exceeds IEC 62271-4 regulations by far.. All devices of this type series are equipped with a semi-automatic control and are easy to operate: The functions are selected by means of

    Get Price
  • Environment ranks first - DILO

    gas hand-ling equipment and SF 6 re-use based on DILO’s “zero emission” philosophy. Pros and cons SF 6 is a non-toxic, inert insulating and quen-ching gas of high dielectric strength and thermal stability and has been successfully used for more than four decades in enclosed medium and high voltage switchgear and circuit breakers. SF 6

    Get Price
  • sf6 gas switchgear End of Life Services dilo

    DILO offers the widest valves and couplings product range in the world. Whether for medium voltage switch- gear, high voltage switchgear or gas-insulated lines (GIL) our products always meet your requirements. The DILO sealing principle prevents the loss of SF 6. Get Price

    Get Price
  • Gas Insullated Switchgear sf6-gas gas filling kit separating unit

    Gas Insullated Switchgear SF 6 gas filling kit separating unit. SF6 GAS | Dilo Company, Inc 6 is a non-toxic, inert insulating and quenching gas of high dielectric strength and thermal stability. Thus, it is used in enclosed medium and high voltage switchgear as an arc quenching and insulating gas due to its properties. sf6 [email protected]

    Get Price
  • Gas Insulated Substation - ENTSO-E

    Results The gas insulated switchgear for HVDC has allowed better use of available space because of its compact size and high reliability. References [1] CIGRÉ 2007: Final Report of the 2004 - 2007 International Enquiry on Reliability of High Voltage Equipment Part 5 - Gas Insulated Switchgear (GIS). [2] Siemens. 8VN1 blue GIS up to 145 kV

    Get Price
  • Multifunctional SF6 gas refilling device compete with Dilo

    RF051 Economy Series SF6 Gas Handling Cart; RF391 Mega Series SF6 Gas Recycling Unit; S100 Micro Series SF6 Gas Recycling Device; RFJ SF6 Refilling Evacuating Devices; RF912 SF6 Gas Analyzer; NA1013 SF6 Gas Monitoring System; RSSSF6 Smart SF6 Sensor; RF300N SF6 Service Cart; SF6 Gas Purification for re-use System; Our Client; Connect us

    Get Price
  • Product brochure Gas-insulated switchgear ELK-14 C, 245 kV

    ABB holds a distinguished record of innovations in gas-insulated switchgear (GIS) technology and our latest ELK-14 series for 245 kV is designed to break several performance barriers. In a power system, switchgear is used to control, protect and isolate electrical equipment thereby enhancing the reliability of electrical supply. With GIS

    Get Price
  • Busch Innovation in Vacuum Award Goes to Dilo | Busch USA

    Dilo was the first company ever to deal with the problem of handling sulfur hexafluoride (SF6) back in the 1960s. Sulfur hexafluoride is used as an insulating gas in electrical switchgear. Dilo has developed technical solutions that prevent this climate-damaging gas from entering the Earths atmosphere.

    Get Price
  • China High voltage electric switchgear,SF6 gas insulated

    The high-voltage switchgear is an electrical equipment based on circuit breakers. It means that the manufacturer connects the relevant high and low voltage electrical appliances (including control appliances, protective appliances, and measuring appliances), bus bars, current-carrying conductors, Insulators, etc. are assembled in a closed or open metal cabinet as a device for receiving and

    Get Price
  • Home - Switchgear Content

    Gas Insulated Switchgear (20) Generator Circuit Breaker (10) HV AC Switchgear (81) High Voltage Circuit Breaker (53) High Voltage Disconnector Switch (17) High Voltage Instrument Transformer (2) LV Switchgear (2) MV AC Switchgear (60) Fault Current Limiter (2) Fuses (3) Gas Switchgear (7) Load Break (2) Recloser (3) Sectinalizer (2) Solid

    Get Price
  • First use in the high-voltage grid: SF6-free circuit

    The high-voltage circuit breakers and gas-insulated switchgear from Siemens – with vacuum-interruption and clean-air technology in the high-voltage range – are upgrades to the circuit breakers and switchgear that work with sulfur hexafluoride (SF 6) as the insulating, switching, and extinguishing gas and will remain in the product line.A vacuum-interrupter unit switches and extinguishes

    Get Price
  • Compact-type gas-insulated switchgear apparatus - HITACHI

    1. A compact-type gas-insulated switchgear apparatus comprising a circuit breaker (1) including a vertical cylindrical casing (6) including arranged therein a breaker (4) on the same axis as the cylindrical casing (6) and a bus-side connecting conductor (2) connected to a lower terminal of the breaker (4) and arranged substantially in parallel to the breaker (4), a cylindrical cable head

edge-iconRelated News
toTop
Click avatar to contact us
Chat Online