News Center
dilo GCB sf 6 separating unit

dilo GCB sf 6 separating unit

Description For quick detection and quantification of small sf6-gas leaks. 3-033-R200 sf 6-LeakSpy (Sensor length 300 mm). The cordless battery-operated sf 6 LeakSpy precisely measures sf6 gas concentration in air by means of a non dispersive infrared sensor (NDIR sensor) and indicates the value on a graphic display in ppm v.The device allows precise localisation of leaks by searching the highest SF ...

[email protected]

News Detail

  • B121R12 /N separating plant - DILO

    The purification technology of the separating unit is based on the SF 6 condensation under pressure at low temperature principle. We recommend using this unit where large SF 6 quantities have to be purified and prepared. The purity degree of the prepared SF 6 gas corresponds to the IEC 60480 guideline for used SF 6 gas. The values measured

    Get Price
  • DEVICES FOR DETERMINATION OF THE SF GAS QUALITY - DILO

    Options (please inquire separately):All devices with percentage measuring system are additionally available for SF 6 concentrations in SF 6 /CF 4 gas mixtures (measuring accuracy: ±2.0 vol.-%). Thus it is possible to switch over between the SF 6 /N 2 and SF 6 /CF 4 measurement. Single measuring device for moisture: -50 to +20&C 3-035R-R102

    Get Price
  • Dilo SF6-LeakSpy SF6 Gas Leak Detectors | CEPCO Sales

    Description For quick detection and quantification of small SF 6 leaks. 3-033-R200 SF 6-LeakSpy (Sensor length 300 mm). The cordless battery-operated SF 6 LeakSpy precisely measures SF 6 concentration in air by means of a non dispersive infrared sensor (NDIR sensor) and indicates the value on a graphic display in ppm v.The device allows precise localisation of leaks by searching the highest SF

    Get Price
  • SF Gas Handling 6 - 50hz Solutions

    DILO SF 6 gas service cart DILO SF 6 gas storage tank SF 6 circuit breaker the air recovered exhausts into the atmosphere Gas cylinder 1. SF 6 gas recovery 2. Evacuation of air or nitrogen 3. Filling with SF 6 (to operating pressure) Functional diagram for service carts Suction pump Compressor Particle fi lterDry fi lter Vacuum pump

    Get Price
  • B131R41 Mobile oilfree suction pump unit - DILO

    Mobile oilfree suction pump unit C 3387-04 The mobile suction pump allows upgrading old SF 6 maintenance devices. Thus it is possible to recover the SF 6 gas from the gas compartment to a final vacuum of 1 mbar by connecting in series the mobile suction pump. Mobile oilfree suction pump unit 15 m3/h Final vacuum < 1 mbar

    Get Price
  • 3-1150-R... | DILO GmbH

    Lock valve for density monitors PN16 DN20 For emission-free disassembly or verifi cation of density monitors. 3-1150-R... Density monitors can be verified directly at the gas compartment or disassembled for external tests without having to recover the gas from switchgear by means of these lock valves.

    Get Price
  • DILO Products – Aspectus Engineering Services Pte Ltd

    SF 6-gas recovery down to < 1 mbar; TM 5.0 B Oil-free Compressor; delivery rate: 6.5 m³/h at medium suction pressure with SF 6; Oil-free suction pump for recovery of SF 6 (15 m³/h, final vacuum < 1 mbar); Vacuum pump for evacuation of air (40 m 3 /h, final vacuum < 1 mbar); Operating and indication of the most important process parameters via 10“ multi-touch panel with protective cover

    Get Price
  • DILO Sealing principle | DILO GmbH

    Features of DILO high pressure tube unions. Leak rate ≤ 1x10-8 mbar l/s; Suitable for pressures up to 1,000 bar and vacuum; Temperature resistant from -270

    Get Price
  • SF6-Gas Circuit Breakers - Adapt Australia

    SF 6 Breaker 800 kV SF 6-Gas Circuit Breakers (GCB) For Out-Door Use From (24 kV To 800 kV) CGL is the only manufacturer in India for supply of 420kV SF6 Circuit Breakers to meet the high altitude requirement of 1600m. The SF6 Gas Circuit Breaker (GCB) Products range is as follow:

    Get Price
  • Comparison Between Vacuum and SF6 Circuit Breaker

    Aug 29, 2018The number of moving parts is higher for the SF6 circuit-breaker than that for the vacuum unit. However, a reliability comparison of the two technologies on the basis of an analysis of the number of components are completely different in regards design,

    Get Price
  • SF6 Gas Recovery,Purification Refilling Unit Manufacturer

    GRT SF6 Gas Recovery, Purification Refilling Unit is main used for manufacture, installation and maintenance of SF6 electrical equipments, such as circuit breakers, GIS(gas insulated switchgears), high-voltage transformers, high-voltage transmission lines, substations, etc. It is composed of vacuum system, compression systems, purification systems, storage system, condensing system and re

    Get Price
  • Our portfolio | DILO GmbH

    Our website uses cookies. These have two functions: On the one hand they are providing basic functionality for this website. On the other hand they allow us to continuously improve our content for you by collecting and evaluating pseudonymised visitor data.

    Get Price
  • sf 6-gas-servicing-equipment-information – ENERVAC

    Sulfur Hexafluoride (SF 6) is an excellent gaseous dielectric for high voltage power applications.It has been used extensively in high voltage circuit breakers and other switchgear employed by the power industry. Applications for SF 6 include gas insulated transmission lines and gas insulated power distribution substations. The combined electrical, physical, chemical and thermal properties

    Get Price
  • DILO - 3-033-R200 - SF6 Gas Measuring Devices - SF6

    DILO - 3-033-R200 - SF6-LeakSpy - SF6 Gas Detectors by DILO Armaturen und Anlagen GmbH. The cordless battery-operated LEAKSPY SF6 precisely measures SF6 concentration in air by means of a non dispersive infrared sensor (NDIR sensor) and indicates the...

edge-iconRelated News
toTop
Click avatar to contact us
Chat Online