sf6-gas recovery down to < 1 mbar; TM 5.0 B Oil-free Compressor; delivery rate: 6.5 m³/h at medium suction pressure with sf 6; Oil-free suction pump for recovery of sf 6 (15 m³/h, final vacuum < 1 mbar); Vacuum pump for evacuation of air (40 m 3 /h, final vacuum < 1 mbar); Operating and indication of the most important process parameters via 10" multi-touch panel with protective cover
[email protected]described the tests performed at site by the AREVA TD team and the recovery of a polluted gas by AVANTEC in their factory, removing the decomposition products. Generally, this paper describes the treatment and the recycling of a used gas. 2/ Introduction Fig.1. Typical 245 kV dead tank circuit breakers using SF6 gas as Fig. 2.
Get PriceSF 6-gas recovery down to < 1 mbar; TM 5.0 B Oil-free Compressor; delivery rate: 6.5 m³/h at medium suction pressure with SF 6; Oil-free suction pump for recovery of SF 6 (15 m³/h, final vacuum < 1 mbar); Vacuum pump for evacuation of air (40 m 3 /h, final vacuum < 1 mbar); Operating and indication of the most important process parameters via 10“ multi-touch panel with protective cover
Get PriceGas release with noise or damage/ explosion of SF6 cylinder will be considered a major gas leak and PIRMP will be activated for such incidents. Since the SF6 recovery plant and SF6 cylinders are stored in a well ventilated area, even with moderate leakage, immediate risk to persons nearby is minimal. However, in case there is a
Get PriceENERVAC’s latest SF6 Gas Recovery Unit incorporates a new and improved high pressure,totally oil-less compressor capable of 1000 psig (7 MPag) of pressure. This new technology allows for liquefaction of SF6 gas even in the warmer climates typical of the southern United States.The cart is ideally
Get PriceDILO - Pre-Filter and Separating Units by DILO Armaturen und Anlagen GmbH. Adsorption of humidity and decomposition products. On the assumption that contaminated or humid gas is in the circuit breaker we recommend the use of pre-filters between switc...
Get PriceSF6 gas 160 plant recovery machines dilo. The compact and mobile small service cart meets all requirements for efficient SF 6 gas handling in the medium voltage range. Compact and ergonomic design was the main focus for its construction. The maintenance unit allows gas recovery down to a final vacuum of [email protected]
Get PriceThe compact and mobile SF6 gas reclaimer meets all requirements for efficient gas handling in the medium voltage range. Compact design and ergonomic aspects have been the main focus for its construction. The maintenance unit allows gas recovery down to a final vacuum of < 5 mbar and keeps pace with large devices. All necessary functions
Get PriceJun 10, 2020XGN15-12/24 AC Metal Enclosed Switchgear Item Unit Parameter Rated voltage KV 3.6,7.2/12 Rated frequency Hz 50 Rated current of breaker A 630,1250,1600,2000,2500,3150 Rated breaking active load current A 630,1250,1600,2000,2500,3150 Rated closed loop breaking current KA 20,25,31.5,40 Rated current under the cable charging breaking current
Get PriceRF051 Economy Series SF6 Gas Handling Cart; RF391 Mega Series SF6 Gas Recycling Unit; S100 Micro Series SF6 Gas Recycling Device; RFJ SF6 Refilling Evacuating Devices; RF912 SF6 Gas Analyzer; NA1013 SF6 Gas Monitoring System; RSSSF6 Smart SF6 Sensor; RF300N SF6 Service Cart; SF6 Gas Purification for re-use System; Our Client; Connect us
Get PriceDILO - Model B071R11 - Portable Separating Filter Unit (pe 25 Bar) For adsorption of oil-aerosols, moisture and gaseous or dusty decomposition products. Separating filters filled with activated carbon granulates and aluminium oxide Al2O3.
Get Pricedilo SF 6 reuse in MALI sf 6 gas Treatment in IRAQ. Sulfur Hexafluoride (SF6) Recovery - GENERON - Gas Solutions 23, 2017 Sulfur hexafluoride, SF 6, is used around the world as a dielectric medium for high-voltage circuit breakers, switchgear, and other electrical equipment.Additionally, it is used for the filling of insulated windows and for
Get PriceDevices and Units) DILO Type L057R01, Economy Series: a. Handling SF6 Gas with safety as per International regulation. b. Recovery (final vacuum of 1 mbar) and putting into storage of SF6-gas from gas compartments. c. The gas compartment can be flooded with air, evacuated and filled with d.
Get PriceThis weighing unit is a useful tool for the stock management of SF6 cylinders and containers in connection with the SF6 Monitoring Manager database software. The integrated interface allows the connection of the operating unit to all DILO weighing scales and gas refilling devices equipped with a serial interface for data exchange or monitoring.
Get PriceThe reconditioning process includes increasing the storage pressure of the gas to allow the start of SF 6 gas liquefaction followed by lowering the temperature by using two to three temperature changes below -40 degrees C. This further helps the liquefaction of SF 6 gas, thus separating other vapors such as N 2, O 2, and CF 4.Upon the start of the reconditioning process, the contaminated SF 6
Office Add: Kexue Revenue, High and New Technology Industrial Development Zone, Zhengzhou, China